Assume that the hole takes 1.25 cu ft of grout [ 35 litres] in this period.
The small take indicates that refusal is near.
SUMMARY OF APPLICATION SO FAR - at 2 hours 30 minutes:
Permeability before grouting is more than 100 lugeons (high)
Water:cement ratio = 0.5:1. Pressure has built up to 50 psi [3.5 bars] and it is necessary to use the
control valve on the standpipe to control it.
Total cement injected so far
To proceed to the next period in the simulation CLICK HERE.